What are the advantages of a VRV System
over central air conditioning systems? |
 |
| Individual control |
 |
| Conventional systems air condition a building as a whole, whereas the VRV system air conditions each room individually. Hence it is ideal for the constantly changing occupancy of a typical building. Even further, precise level control is possible that reacts to the exact conditions in each room. Individual control promotes a far more economical and efficient system. |
 |
Other advantages
|
 |
| Saves energy |
| • |
Using the HRV for ventilation dramatically boosts energy efficiency. |
| |
| Conserves space |
| • |
Space efficiency is enhanced by the compact size of the individual units, the long maximum piping length, and the ability to realize a largescale air conditioning system with a single piping circuit |
| |
|
| Offers a wide selection of models |
| • |
Lineup of heat pump types and cooling only are 5 to 54 HP, and both in 2 HP increments*. Indoor units consist of 14 types with a total of 79 models. This wide selection of models makes it possible to build a system that perfectly suits the customer’s requirements. |
| • |
Except for 5 HP |
| |
|
| Operates over a broad temperature range |
| • |
The lower end of the operating temperature range in heating has been extended from –15°C to – 20°C. |
| |
|
Provides superior design flexibility
|
| • |
The extended maximum piping length gives more flexibility when designing the system. |
| • |
Layout changes can be made easily because the capacity of the indoor units can be up to 200% that of the outdoor units. |
| • |
New compressor technology eliminates the need for piping calculations, which shortens the time needed for design. |
| • |
Outdoor units can be placed on the roof where they have no effect on the design of the building interior. |
| |
|
Enhances ease of use
|
| • |
Units are designed to operate quietly, and are also equipped with a function for silent operation especially at night. |
| • |
The controller is easy to operate and has many useful functions. Units can be controlled in each individual room. |
| |
|
Delivers ultimate reliability
|
| • |
The self-diagnostic system identifies problems within the system quickly and accurately. |
| • |
The Auto Restart function ensures that operation is restored with the previous settings even if the power has been shut off. |
| • |
Units are controlled in each individual room, so local malfunctions does not cause the entire system to shut down. |
| |
|
| Simplifies installation |
| • |
The lightweight, compact units can be transported using a regular lift. |
| • |
Units can be installed on each floor. |
| • |
The pipes are few in number, making layout simpler. |
| • |
Inspection after installation is straightforward. |